Safety, Fire & Survival · Fire — Structural Fire Protection Classes

In SOLAS structural fire protection, the difference between an 'A' class and a 'B' class division is that A-class divisions are:

Explanation

A-class divisions are steel or equivalent, capable of preventing the passage of flame and smoke for one hour, and insulated so the unexposed side stays below set temperature limits for a rated time (A-60, A-30, A-15, A-0). B-class divisions are non-combustible but to a lesser standard; C-class are merely non-combustible.

Authority: SOLAS II-2; FSS Code